+371 26485222 · +371 67 505 603 | info@cortex.lv | Installer portal
IF-1.4id(V2) Switching Interface

IF-1.4id(V2) Switching Interface

Interface for connecting alarm panels with a telephone communicator to CORTEX transmitters. Jumper JP1 selects whether the panel account is changed to 9999 or kept, so several panels can be connected to one transmitter.

DSCParadoxNXContact ID
Mon–Fri 9:00–17:00

Description

The IF-1.4id (V2) connects alarm panels with a telephone communicator to CORTEX transmitters. It is connected between the panel telephone communicator and the transmitter communication port; to the panel it is a central station, so any panel with Contact ID format works — DSC, Paradox, NX and others. Unlike the previous IF-1.4id, the communicator can be programmed to dial any number with any number of digits.

With jumper JP1 closed, the interface changes any panel account to 9999 and the transmitter sends events to the monitoring centre with its own account number. With JP1 open, events are passed on with the panel account — useful when several panels are connected to one CORTEX transmitter through several interfaces. This is what sets the IF-1.4id (V2) apart from the IF-1.5id (V2).

Specifications

Compatible panelsany panel with a telephone communicator and Contact ID (DSC, Paradox, NX and others)
Connectionbetween the panel telephone communicator and the transmitter communication port
Data formatContact ID (other formats not supported)
Dial numberany number with any number of digits
Panel account (JP1 closed)changed to 9999 — the transmitter sends events with its own account
Panel account (JP1 open)kept — events arrive with the panel account
Several panelsthrough several interfaces to one transmitter (unlike the IF-1.5id(V2))
Difference from IF-1.4idany dial number, account replacement set by JP1
Power supply12V

Documentation

All documents and software →

Other products in this category